Main station|Member Center|Save the desktop|Mobile browsing
Ordinary Member

Hainan Geke

Home appliance cleaning agent, home appliance cleaning equipment

sell
  • There is no classification
contact
  • Contact:冯彬
  • Phone:18808986523
  • Email:1485256704@qq.com
search
 
link
  • There is no link yet
home > sell > Why should we clean PERT floor heating pipes? How often should it be cleaned? Who should I call for cleaning?
Why should we clean PERT floor heating pipes? How often should it be cleaned? Who should I call for cleaning?
products: Views:5Why should we clean PERT floor heating pipes? How often should it be cleaned? Who should I call for cleaning? 
brand: 格科
规格: 450ml
箱: 25瓶
保质期: 3年
price: 1.00元/箱
MOQ: 1 箱
Total supply: 99999 箱
Delivery date: Shipped within 3 days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2016-10-09 16:35
 
Details
Why should we clean R floor heating pipes? How often should it be cleaned? Who should I call for cleaning?
1. Why do floor heating pipes need to be cleaned?
Question: Isn’t the designed service life of floor heating pipes more than fifty years? Why do you need to clean it? Answer: There is no problem with geothermal pipes for a hundred years, let alone fifty years. A medium must pass through the pipe, and the medium is water. Water contains a lot of substances, which can be roughly divided into two categories: one is minerals, and calcium and magnesium ions are one of them. We all have common sense in life, and the water temperature is high and low. Changes in calcium and magnesium ions will combine to form dirt. Although the heating water has been softened, due to too much heating water loss (especially the loss of floor heating is greater than that of traditional heating), most of the heating water replenishment is not softened ideally, so There will still be a lot of calcium and magnesium ions in the water. The other type is microorganisms. When viewed under a microscope, when the boiler water is above degrees Celsius, some flocs will be produced in the water. As the water temperature rises, the flocs will increase and attach to the water. Biological slime forms on the scaled pipe walls. Jiajia geothermal coils have inherent characteristics such as complex shapes and long pipelines. Pipe scale will form after a certain period of time. In severe cases, it will cause pipeline embolism and affect the heat dissipation effect. So the geothermal pipes need to be cleaned.
/>
Question: Does it still need to be cleaned if the temperature at home is very high? Answer: It needs to be cleaned. Nowadays, there are two methods of heating in cities: floor heating and traditional heating, so the water supply temperature is relatively high (the water supply temperature for floor heating should be around 10 degrees Celsius, and the water supply temperature for traditional heating should be around 10 degrees Celsius). As a result, floor heating users have higher temperatures in their homes. Some floor heating users turn down or close the water supply valve, which causes the water flow in the floor heating pipes to slow down, forming pipe sediments, which is more likely to cause pipe embolism, so it should be cleaned.
, Q: How often should it be cleaned? Do you need to clean it just after entering the house? Answer: Professional cleaning is required once every two years. If the geothermal service life exceeds two heating periods, regular maintenance and upkeep are required. It is best to clean it once when you first enter the house. There are some unprofessional geothermal constructions, and there will be impurities, stones, and cement in the pipes. In serious cases, if the filter is not installed, it is easy to cause the geothermal pipes to be blocked in a short time.
, Q: When can it be cleaned? Answer: It can be cleaned all year round. The best time to clean is after heating is stopped to completely remove the dirt, biological slime, impurities and bacteria formed in the pipelines during the heating period. This is to prevent sediments from forming in the pipes and causing pipe embolism, so that the floor heating pipes can be clean for the next heating period.
. How many cleaning methods are there? Answer: There are many methods for geothermal cleaning, including tap water washing, chemical washing, high-pressure projectile cleaning, pulse physical wave cleaning combined with drugs, etc.
What will be the impact if the floor heating pipes are not cleaned? Answer: According to relevant statistics, during the heating process, every time dirt is added to the inner wall of the geothermal pipe, the ambient temperature will drop by ℃. This not only affects the normal temperature, but also causes a waste of energy. Continued use will cause pipeline embolism. The solution can only be solved by removing the ground and replacing the floor heating pipes, which will cause property losses and inconvenience to the floor heating users. , Why should geothermal heating be cleaned and maintained regularly
With the widespread use of ground radiant heating in new industrial and civil buildings, ground radiant heating has been regarded as the preferred heating method. With the increase in geothermal heating users, many doubts and difficulties have arisen. Solved problems ensue. The main forms of ground radiant heating are electric heating direct radiation method and water heating pipe radiation method. More than % of buildings in our country use the radiant water heating pipe method.
/>&#&#
Since the water contains a large number of microorganisms, a large amount of biological slime will be produced under suitable conditions. The biological slime will cover the inside of the pipe wall, causing the pipe to turn green and Black, according to relevant statistics, in the geothermal heating system, every time scale increases on the inner wall of the floor heating pipe, the ambient temperature will drop by degrees Celsius. This not only affects the normal operating temperature, but also causes a waste of energy. For example, if the effective temperature is not reached for a long time, Cleaning treatment will cause the geothermal heating system to malfunction, causing the embolism in the pipe to become unusable, and even causing the ground to be damaged, dismantling or replacing the geothermal pipe system, causing property losses and inconvenience to the floor heating users. The working principle of geothermal cleaning equipment is to use compressed air as the driving force, and use a launcher to launch a special projectile that is larger than the inner diameter of the pipeline to a certain standard, so that the projectile moves along the pipeline at high speed and fully rubs against the inner wall of the pipeline, achieving Dry physical cleaning technology for cleaning the inner walls of pipelines. It can pass through complex multi-bend pipelines such as curved, circular, circular, spiral, and snake-shaped pipelines, and can effectively remove calcium and magnesium ion scale and biological slime inside the geothermal coil. Other residual impurities can easily solve the problem of pipeline embolism.
2. The necessity of cleaning floor heating pipes
After a floor heating pipe is used for a period of time, a large amount of slime, bacteria and scale will be produced on the inner wall of the pipe, which will adhere to the inner wall of the pipe, causing blockage of the pipe and resulting in poor water circulation. Smooth and insufficient heat dissipation will seriously affect the heating temperature and effect. Some data show that after one year of use of floor heating, every increase in dirt on the inner wall of the floor heating pipe will cause the temperature in the heating room to drop by ℃. This not only affects the normal use of floor heating, but also causes a waste of energy. The traditional floor heating cleaning method is to use high-pressure water flushing. Although this method is simple, the cleaning is not thorough enough, especially the dirt adhering to the pipe wall is difficult to effectively clean.
3. Floor heating pipe cleaning process
Open the floor heating hot water inlet pipe
Press the bottle of this product: dilute and inject it into the hot water inlet pipe
Make sure the floor heating pipe is filled with water. Close the cold water valve, start the circulation pump and circulate for minutes
. Open the cold water valve and drain the turbid water
. Rinse the floor heating pipe with clean water until clean water flows out of the outlet pipe, and the cleaning work is completed.
The products supplied by our company include: water dispenser cleaning agent, refrigerator cleaning agent, air conditioning cleaning agent, solar water tank descaling agent, soy milk machine descaling agent, range hood cleaning agent, hood cleaner, microphone and telephone disinfectant , stainless steel cleaning powder, boiler descaler, floor heating pipe descaler, floor wax, car wax, leather cleaning paste and other cleaning, disinfection and descaling supplies.
The manufacturer’s national investment promotion is authorized for one place in one region. The number of places is limited. Please sign up as soon as possible!
(Consulting manufacturer investment hotline: Same as WeChat)
Consulting manufacturer investment: This is work, please indicate the reason for extra time
Consulting manufacturer investment project person in charge: Feng Bin (manager)
/> Address: Haikou National High-tech Industrial Development Zone & Meijia Industrial Park, Haikou, Hainan Province
/>
Request for quotation
A total of0articles  Related Comments: